FAQ
HARDWARE: How to adjust the pyrometer temperature measurement again?
The pyrometer measurement is never adjusted automatically, only manually. Therefore an offset for the pyrometer can be configured in the sensor settings. Precondition is an installed sensor firmware version from 1.8 on and an iOS app version from 1.5 on. Please measure the road temperature with a reliable reference instrument at the same spot, after MARWIS has been running for at least 10 minutes and the LED have switched to green already. Then, adjust the temperature measurement in the setting menu. For this, the –/-/+/++ buttons must be pushed until the wished temperature is reached (after pushing the buttons wait until the pyrometer is updated with the new emission level). Sensor configuration description on iOS app help as well as on the Android App help website.
Back to list